13931


View Complete Specifications

Specifications

REV.

 

DESCRIPTION

DATE

1.

 

Change Color Rotation, add VW-1, adjust electrical performance, add PN

6/9/2010

2

 

Added second jacket for roundness and connector fit

7/15/2010

3

 

Change Primary Colors

11/15/2010

4

 

Change ACR requirements

9/14/2010

5

 

add drain wire and color change and view of cable

12/1/2010

6

acket fusing requirement

12/13/2010

 

 

 

 

 

Physical Data

 

 

Dimensions (Nom.)

 

Description

 

inches

mm

1.

Strength member

Multi-Strand 7X19 1/16" 302/304 Stainless Steel conductor
300 pound minimum break strength

0.064

1.63

2.

Crossweb

HDPE

 

 

3.

Conductor:

18 AWG 19/.0092" Tinned Copper

0.045

1.14

4.

Insulation:

EXRAD 150 UT, .030" wall, meets requirements of SAE J1128 GXL

0.105

 

2.67

 

Cable:

(4) primaries around crossweb

0.300

7.62

5.

Shield:

2 mil Aluminum/polyester spirally applied

0.305

7.75

6.

Drain

Braided 3X40 AWG TC .053" X .014" 24 AWG equivalent

 

 

7.

Braid:

36 AWG Tinned copper 85% min coverage

0.325

8.26

8.

Inner Jacket:

Extruded EXRAD XLE, .040" nom wall

0.405

10.30

9.

Outer Jacket:

Extruded EXRAD XLE, .040" nom wall

0.485

12.33

 

 

Both jackets to be fused and not readily seperable

 

 

 

Print

Champlain Cable / Molex XXXXX

 

 

 

 

XXXXX = 5 Character ID number

 

 

Technical Data

Temp. Range:

-40 ºC to +125 ºC

 

 

 

Voltage Rating:

300 Volts

 

 

 

Flame Rating:

VW-1

 

 

 

Bend Radius:

4x cable diameter - single bend

 

 

* Impedance:

100 Ohms +/- 15 Ohms (white/blue) and (orange/yellow)

 

 

* ACR:

> 10 dB (1 to 31.25 MHz)

 

 

Cable Pull Strength: Greater than 300 pounds

*Electrical performance to be monitored during several production lots. Parameters to be adjusted after analyzing data. Cable rotation must match the drawing when looking at the end of the cable as it is payed off a spool.

 

The information on this drawing is the proprietary property of Champlain Cable Corporation,and may not be used, reproduced or disclosed to others in whole or in part without written authorization.
ETF-011 Owner: RF Business Unit Manager - Approved By: VP of Operations / 27 February 2004

 