DATACLEAR® MIL-DTL-24643/77 CAT 6A Ethernet

    Product features:
  • Low Smoke, Zero Halogen
  • 10GBASE-T
  • Interoperability

Champlain Cable has a long history of success in the development and manufacture of data communication cables.  We are the first supplier to be listed on the QPL database by the US Naval Sea Systems Command (NAVSEA) for all variants of MIL-DTL 24643/77 Cat 6A Ethernet cable.

Dataclear® Marine/77 Ethernet Cable provides  significant  improvements to  the  previous M24643/59 Cat 5e standard bringing substantially more data-carrying capacity in a similar cable size, headroom for future technology improvements, and interoperability via termination into a standard RJ-45 jack.   Supports 10GBASE-T systems.

  • High Temperature Rating: 80°C
  • Low Temperature Rating: -20°C
  • Voltage Rating: 300V

Specifications

MIL-DTL
24643/77 PN
Type Pairs Conductor Shield Water-blocked Jacket Color Weight / KFT (lbs) Bend Radius (inch / min) Nom          Cable OD
-01UO LSC6FS-4 4 23, solid BC Foil No Black 54.6 1.5" 0.355"
-02UO LSC6OS-4 4 23, solid BC Foil + Braid No Black 70 1.5" 0.375"
-03UO LSC6OSW-4 4 23, solid BC Foil + Braid Yes Black 81.3 2.5" 0.410"
ELECTRICAL PROPERTIES
DC Resistance (Ohms/100m) 9.38 max
DC Resistance Unbalance 4% max
Input Impedance (1 MHz – 500MHz) 100 Ohms ±15%
Frequency 1.0 10.0 31.25 62.5 100.0 500.0
Return Loss dB/100m (min) 20.0 25.0 23.6 21.5 20.1 15.2
Insertion Loss dB/100m (max) 2.1 5.9 10.5 15.0 19.1 45.3
NEXT dB/100m (min) 72.3 59.3 51.9 47.4 44.3 33.8
ACRF [ELFEXT] dB/100m (min) 67.8 47.8 37.9 31.9 27.8 13.8
PS NEXT dB/100m (min) 72.3 57.3 49.9 45.4 42.3 31.8
PSACRF [PS ELFEXT] dB/100m (min) 64.8 44.8 34.9 28.9 24.8 10.8
TCL dB (min) 40.0 40.0 35.1 32.0 30.0 23
Propagation Delay ns/100m (max) 570 545 540 539 538 536
Delay Skew ns/100m (max) 45 45 45 45 45 45

 

PHYSICAL PROPERTIES
      Tensile Strength
          Insulation  (Un-aged) 450 min
          Insulation 75%
         Jacket       (Un-aged) 1300 min
         Jacket       (Retention after 168hrs at 136oC) 60%
      Elongation
          Insulation (Un-aged) 450 min
          Insulation (Retention after 48hrs at 100oC) 75%
         Jacket       (Un-aged) 1300 min
         Jacket       (Retention after 168hrs at 136°C) 60%
      Cross-link proof test (Jacket, Percent maximum) 50%
      Flame Propagation (Cable) No Failure