EXAR® 150 UL 3680

Exar® 150 UT is a lower cost and very thin 150°C insulated hookup wire with a wide operating temperature range. Irradiation cross-linking assures this insulation will not melt or flow at soldering temperatures.  It has excellent mechanical strength, cut through resistance and good chemical and solvent resistance.

Exar 150UT processes very well on automated high speed cut and strip equipment. Cone-packs are available to maximize the through-put on the fastest automated cut, strip and terminate equipment and reduce cost. The end result is a hookup wire ideally suited to applications where a combination of flexibility, size and performance is required.

  • High Temperature Rating: 150°C
  • Low Temperature Rating: -55°C
  • Voltage Rating: 600V
  • Flame Resistance: FT-2
  • Oil Temperature Rating: 60°C
  • Ultraviolet Resistance: Black
  • Radiation Resistance: No
  • Flexibility Rating: 3
  • Fluid Resistance Rating: 4
  • Cut-Through Resistance Rating: 4

Specifications

 

Product

Number

 

Conductor

Tinned Copper

Nom.  Conductor

Diameter

         in.            mm.

 Nom. Insulation

Thickness

      in.            mm.

Nom. Finished

Diameter

      in.            mm.

Nom.  Finished

Weight

(lbs/mft)

 

Ampacity

40°C, Free Air

3680-26/XX-B0 26 (7/34)      .019            .48    .016           .41    .051          1.30 1.80 3
3680-26/XX-E0   26 (19/38)      .020            .51    .016           .41    .053          1.35 1.87 3
3680-24/XX-B0 24 (7/32)      .024            .61    .016           .41    .056          1.42 2.43 7
3680-24/XX-E0   24 (19/36)      .024            .61    .016           .41    .057          1.45 2.48 7
3680-22/XX-B0 22 (7/30)      .030            .76    .016           .41    .062          1.58 3.40 14
3680-22/XX-E0 22 (19/34)      .031            .79    .016           .41    .063          1.60 3.51 14
3680-20/XX-B0 20 (7/28)      .038            .97    .016           .41    .070          1.78 4.89 18
3680-20/XX-E0 20 (19/32)      .038            .97    .016           .41    .071          1.80 5.10 18
3680-18/XX-B0 18 (7/.0152)      .045         1.14    .016           .41    .077          1.96 6.55 24
3680-18/XX-D0 18 (19/.0092)      .045         1.14    .016           .41    .077          1.96 6.45 24
3680-16/XX-F0 16 (26/30)      .058         1.47    .016           .41    .092          2.34 9.99 31
3680-14/XX-H0 14 (41/30)      .071         1.85    .016           .41    .107          2.72 15.07 46
3680-12/XX-J0 12 (65/30)      .089         2.26    .016           .41    .121          3.07 23.08 60
3680-10/XX-J0 10 (65/28)      .111         2.81    .017           .43    .145          3.68 34.25 80
PROPERTIES EXAR® 150 UT
Approvals / Listings:
UL STYLE 3680
CSA AWM 150°C  600V
Physical:  
Temperature Rating   150°C
Voltage Rating (Vrms) 600V
Flexibility - 7 days @ 180 °C Passes
Cold Bend  - 4h @ -65°C Passes
Shore “A” Hardness 98
Shore “D” Hardness 55
Bend Radius 5 X overall diameter
Tensile Strength:
Unaged 3000 PSI
Retention after 7 days @ 180 °C Passes (100%)
Elongation:
Unaged 375%
Retention after 7 days @ 180 °C 100%
Flame Test:  
 UL 758 and FT-2 Horizontal Flame Test Passes
Chemical Resistance
  Acetone swell@23°C/24h 5-10%
  Acid – H2SO4 S.G. 1.260 5% swell@23°C** <1%
  Engine Oil – ASTM D-471 IRM-902 swell@50°C** 1%
  Benzene swell@23°C/24h Not recommended
  Epoxy swell@23°C/24h <5%
  Gasoline – ASTM D-471 Fuel C swell@23°C** 2%
  Methanol swell@23°C** 1%
  Toluene swell@23°C/24h Not recommended
  Xylene swell@23°C/24h Not recommended
Electrical:
  Dielectric Constant 2.48