EXRAD® 150FX Thick Wall ISO Battery Cable

    Product features:
  • ISO 6722-1 Class D Thick Wall
  • 150°C 1000V

EXRAD® 150FX ISO 6722-1 thick-wall battery cable is designed specifically to handle the higher voltage and electrical currents required by today’s hybrid and battery power vehicles. Our thin and high temperature insulations allow for lower weight and less space.

EXRAD 150 FX ISO 6722-1 battery cables have an irradiated cross-linked polyolefin insulation able to withstand temperatures of 240°C and higher. The EXRAD high flex conductor and insulation are designed to be thinner and lighter than other high voltage cables. It is extremely flexible for easy routing in the tight confined areas of the car platform, yet tough enough to withstand the roughest environments. EXRAD FX can be routed through twists and turns where other cables can not. Save money and reduce weight by shortening the cable length.

The end result is the EXRAD 150FX wire is ideally suited to applications, especially conventional, hybrid and electric vehicles where a combination of flexibility, long life and performance is required. ROHS and CE Compliant.

  • High Temperature Rating: 150°C
  • Low Temperature Rating: -70°C
  • Voltage Rating: 1000V
  • Flame Resistance: FT-1
  • Oil Temperature Rating: 60°C
  • Ultraviolet Resistance: Black
  • Radiation Resistance: No
  • Flexibility Rating: 3
  • Fluid Resistance Rating: 4
  • Cut-Through Resistance Rating: 3

Specifications

 

Product Number

 

Std. Conductors Bare Copper**

Nom.  Conductor

Diameter

mm.       in.

Nom. Insulation              

Thickness

mm.       in.

Nom.  Finished

Diameter

mm.          in.

Min. Static

Bend Radius

mm.       in.

Finished

Weight     

KG/KM

Conductor Resistance       per KM* at 20°C
EXRAD–FXIH-6      6.0mm² (84/.30)       2.92      .115      1.06       .042        4.80     .189    24         1.0   68 3.01
EXRAD-FXIH-10    10mm² (80/.40)       3.99      .157      1.06       .042        6.20     .244    31         1.3 112 1.78
EXRAD–FXIH-12    12mm² (154/.32)       4.88      .192      1.06       .042        7.00     .276    35         1.4 134 1.47
EXRAD–FXIH-16    16mm² (105/.46)       5.21      .205      1.24       .049        8.00     .314    40         1.6 208 1.13
EXRAD-FXIH-20    20mm² (247/.32)       6.17      .243      1.24       .049        8.60     .339    43         1.7 216 0.91
EXRAD-FXIH-25    25mm² (798/.20)       6.85      .269      1.24       .049        9.90     .390    50         2.0 261 0.72
EXRAD-FXIH-35    35mm² (551/.28)       8.12      .320      1.24       .049     10.60     .417    53         2.1 356 0.52
EXRAD-FXIH-40    40mm² (494/.32)       8.89      .350      1.27       .050     11.80     .464    59         2.3 419 0.47
EXRAD-FXIH-50    50mm² (798/.28)       9.91      .390      1.27       .050     12.50     .492    63         2.5 509 0.36
EXRAD-FXIH-70   70mm² (1140/.28)    11.83      .466      1.40       .055     14.50     .571    87         3.4 711 0.26
EXRAD-FXIH-95   95mm² (1938/.25)   13.20      .521      1.90       .075     17.00     .669   102        4.1 968 0.19
EXRAD-FXIH-120 120mm² (2442/.25)   15.24      .600      1.90       .075     19.04     .750   112        4.5 1211 0.15
Section Description Requirement Typical Results (70mm2 Sample)
5.1 Outside Cable Diameter 15.50 max. 14.47mm Pass
5.2 Insulation Thickness 1.204mm min. 1.22mm Pass
5.3 Conductor Diameter 12.50mm max. 12.09mm Pass
5.4 Conductor Resistance 0.259 mΩ/m @20oC max. 0.242 mΩ/m Pass
5.5 Withstand Voltage 1000V  5kV no dielectric breakdown Pass
5.6 Insulation Faults Sparktest @ 12.5V no faults Pass
5.7 Insulation Volume Resistivity 109  Ω/mm min. 3.103 X 1017 Ω /mm Pass
5.8 Pressure at High Temperature ‘under load @150oC no dielectric breakdown No breakdown Pass
5.9 Strip Force / Adhesion Per customer agreement NA NA
5.10 Low Temperature Winding 3 tns 30kgm - 40oC no  breakdown no dielectric breakdown, Pass
5.11 Impact 400gm @-40oC no breakdown no breakdown, Pass
5.12.4.1 Sandpaper Abrasion NA NA Pass
5.12.4.2 Scrape Abrasion NA NA Pass
5.13 Long-Term Heat Aging 150oC 3000 hours no breakdown, no cracks Pass
5.15 Thermal Overload 200oC 6 hours no breakdown, no cracks Pass
5.16 Shrinkage by heat 2mm max. 150oC no shrinkage, Pass
5.17 Fluid Compatibility Gasoline 15% max. 7.5% Pass
Diesel Fuel 15% max. 2.7% Pass
Engine Oil 15% max. 3.2% Pass
Ethanol 15% max. 4.7% Pass
Power Steering 30% max 4.1% Pass
Automatic Transmission 25% max 3.2% Pass
Engine Coolant 15% max 0.4% Pass
Battery Acid no breakdown no breakdown, Pass
5.19 Ozone Resistance 45oC 85% Relative Humidity, 70 hours, Ozone 50 +/- 5 pphm 1kV 1 min. (no breakdown) no breakdown, Pass
5.20 Resistance to hot water not less than 10-9 Ohm-mm 1.82 X 10-16  Ohm-mm Pass
5.21 Temperature and Humidity Cycling 40 - 8 hours cycles -40oC and 125oC 80 -100% relative humidity no dielectric breakdown, no cracking Pass
5.22 Resistance to Flame 70 sec. max. 50mm unburned 0 - 1 sec. after burn Pass