EXRAD®RTW Thin-Wall Rail Car Wire
-
Product features:
- Space Savings
- NYCT TX-TW
- Flame Resistant
EXRAD® RTW thin-wall rail car wire is a tough dual-layer insulation system meeting the rigorous requirements of New York City Transit’s TX-TW specification. EXRAD RTW is ideal for the harsh environment of rail cars where the wiring can be subjected to a multitude of challenging physical and environmental stresses. Flexible, fluid resistant and durable, this thin-wall construction utilizes up to 1/3 less space than standard-wall wiring, allowing for more circuits to be located in limited spaces.
- High Temperature Rating: 125°C
- Low Temperature Rating: -40°C
- Voltage Rating: 600V
- Flame Resistance: FT-4
- Oil Temperature Rating: 150°C
- Flexibility Rating: 3
- Fluid Resistance Rating: 5
- Cut-Through Resistance Rating: 5
Specifications
Product
Number |
AWG
(Tin Copper) |
Conductor | Wall Thickness | Finished OD
Nom. / Max. |
Weight
LBS/KFT |
|
OD | Resistance* | |||||
EXRAD-RTW-22 | 22 (19/34) | 0.030 | 15.85 | 0.015 | 0.060 / 0.063 | 3.7 |
EXRAD-RTW-20 | 20 (19/32) | 0.038 | 9.7 | 0.015 | 0.068 / 0.071 | 5.4 |
EXRAD-RTW-18 | 18 (19/30) | 0.048 | 6.21 | 0.015 | 0.078 / 0.080 | 7.8 |
EXRAD-RTW-16 | 16 (19/29) | 0.054 | 4.79 | 0.015 | 0.084 / 0.087 | 9.6 |
EXRAD-RTW-14 | 14 (19/27) | 0.067 | 3.04 | 0.015 | 0.095 / 0.097 | 14.5 |
EXRAD-RTW-12 | 12 (19/25) | 0.085 | 1.91 | 0.015 | 0.115 / 0.118 | 22.0 |
EXRAD-RTW-10 | 10 (27/24) | 0.116 | 1.05 | 0.015 | 0.146 / 0.155 | 38.0 |